Download PDFOpen PDF in browser

Sensitivity Analysis of System of Three Units Having Standby Units and Having Degradation in Main Unit

EasyChair Preprint no. 9523

10 pagesDate: January 3, 2023

Abstract

Here, a stochastic model is created utilizing a single repair facility for a standby system with three identical units. A server is a type of repair facility that responds right away to system problems that arise during system operation. For failure and repair times of the system with various parameters, the most significant monotonically declining lifetime Lindley distribution is used. The primary unit in this study is quite expensive and has two different sorts of deteriorated states in which it can run before changing to D. For random values of the shape parameter related to failure and repair times, the reliability measures' behavior has been graphically depicted. Graphs and tables are employed in order to demonstrate system behavior.

Keyphrases: circuits, degradation, Preventive Maintenance, Regenerative Point Graphical Technique (RPGT)

BibTeX entry
BibTeX does not have the right entry for preprints. This is a hack for producing the correct reference:
@Booklet{EasyChair:9523,
  author = {Shakuntla Singla and Diksha Mangla},
  title = {Sensitivity Analysis of System of Three Units Having Standby Units and Having Degradation in Main Unit},
  howpublished = {EasyChair Preprint no. 9523},

  year = {EasyChair, 2023}}